Furnace & heating
Heat pumps
Ductless mini splits
GoodmanSeasonal tune-up and full diagnostic on your Carrier, Trane, or Goodman system - readings shown to you before any repair is proposed
Diagnosis first, numbers second - you approve the repair price before a single part goes in.
Get your free estimateRheem Heat Pump Service: The Dallas Owner’s Guide
Rheem heat pump service in Dallas typically runs $150 to $650 installed depending on the part, and most jobs are done same day when we have the part on the truck. We stock common Rheem-specific components for the RP14, RP15, RP16, and RP17 series, along with the Prestige and Classic lines. What usually brings owners to this page is a system that’s running but not heating or cooling right, a breaker that tripped and won’t stay reset, or a defrost board blinking a code on the outdoor unit in the middle of a Dallas cold snap.

The good news: most Rheem failures we see are single-component issues, not system-wide failures. A capacitor, a defrost sensor, a reversing valve solenoid coil, a contactor. We identify the exact part, match it to your serial number, put the price in writing, and have it installed same day in most Dallas neighborhoods, including Oak Cliff, Lakewood, Garland, and Mesquite.
Which Rheem Models This Applies To
We service the full Rheem residential heat pump lineup sold in Dallas over the last fifteen years. That means the RP14 (the entry-level 14 SEER workhorse), RP15 and RP16 (mid-tier with better humidity control), RP17 (three-stage, variable-speed), and the Prestige series built on the same platform with better sound ratings. If you have a Rheem Classic from the 2005 to 2015 era, we still stock the common failures for those too: crankcase heater thermostats, time-delay relays, and the older yellow-label defrost controls.
Here’s the compatibility gotcha that costs owners time and return trips: Rheem changed defrost control boards between the RP14 and RP16 generations, and the visual difference is subtle. The RP14 board uses a single-pin jumper configuration. The RP16 board uses a two-row pin header. Plug a generic “universal” defrost board into an RP16 and you may get a system that cools fine but won’t shift into heat mode. We match boards by the exact model number printed on the control board itself, not the data plate on the cabinet. That’s the level of match we do before ordering or pulling a part off the truck.
On the OEM versus aftermarket question: for capacitors, contactors, and relays, we often use quality aftermarket parts that meet or exceed Rheem’s spec. For control boards, thermistors, and reversing valves, we use OEM Rheem parts because the firmware and resistance tolerances are too tight to gamble on. You’ll see the part manufacturer and part number on your written quote so there’s no guesswork about what’s going in your system.
Styles & brands we work with




Signs Your Rheem Heat Pump Service Is Failing
- Outdoor unit runs but air from the vents is lukewarm. This typically points to a reversing valve not shifting. In cooling season the valve sits one way; in heating season it must flip. A failed solenoid coil or a sticking valve body keeps it cooling when you need heat. This is the most common Rheem heat pump failure we see in Dallas winter months.
- The outdoor unit is covered in frost and won’t thaw. Rheem heat pumps frost lightly in cold weather, then the defrost board cycles the system to melt it. If frost builds into a solid block, either the defrost sensor has gone open, the defrost board has stopped signaling, or the accumulation timer has failed. We check the actual board code light, not guess at it.
- The breaker trips and resets once, then trips again. Repeated breaker trips on a Rheem heat pump usually mean the compressor is trying to start against a dead run capacitor, or the crankcase heater has shorted. Do not keep resetting it. Each reset cycle stresses the compressor windings and can turn a $95 capacitor job into a full compressor replacement.
- You hear a loud buzz from the outdoor unit, then silence. That’s the contactor coil pulling in but the contacts failing to close cleanly. Rheem uses a single-pole contactor on many RP14 and RP15 units, and the points pit over time, especially in Dallas where summer heat cycles the unit hundreds of times a season. A pitted contactor will eventually arc and burn.
- The system runs constantly and the electric bill climbs, but the house holds temperature only when there’s no sun. That’s often a run capacitor losing microfarads, not a low refrigerant charge. We test capacitance under load before adding refrigerant. In a Dallas July, a heat pump can’t reject heat efficiently and the head pressure climbs, which is hard on every component, but the run capacitor is usually the first to give.
See the difference
Before
After
Before
After
Before
AfterReplacement Cost & What’s Included
For Rheem heat pump service in Dallas, most component replacements land between $150 and $650 installed. The low end covers start capacitors, run capacitors, contactors, and crankcase heater thermostats. The mid range covers defrost sensors, thermistors, fan motors, and small relays. The upper end covers defrost control boards, reversing valve solenoid coils, and certain time-delay relays keyed to Rheem serial numbers. A full reversing valve body replacement is a separate job that runs higher because the refrigerant circuit has to be recovered and resealed, but that is rare compared to solenoid coil failure.
Every repair from Dalton Heating & Air Dallas includes a written price before the first tool comes off the truck. You’ll see the part number, the installed price, and what the labor covers, all on paper before we start. If the same part fails within the guarantee period, we return at no charge. That’s the 365-Day Done Right Promise, not a 30-day window. Marco Benitez, our Owner & Lead Technician, has a phrase he uses on every job: “Tell me what’s wrong, I’ll tell you what it costs – in writing, before we start.” That’s how we run every call, Rheem or otherwise.
DIY or Call Us?
There are three things an owner can safely check on a Rheem heat pump before calling: the air filter (a clogged filter raises head pressure and makes every part work harder), the thermostat setting (verify it’s actually calling for heat, not in emergency heat mode), and the outdoor unit disconnect box (a flipped switch looks identical to a blown contactor). These checks take five minutes and cost nothing.
What we don’t recommend is opening the outdoor unit cabinet. The run capacitor holds a charge even with power off, and a discharge across your hand or a tool is a real shock risk. The reversing valve and compressor circuit carry 240 volts. If you’ve done the basic checks and the system still won’t run or won’t shift, call (254) 280-5320. We’ll have a background-checked, uniformed technician out to your Dallas home with the common Rheem parts already on the truck. Most jobs are done same day, before you’ve finished the second pot of coffee.
FAQs
In Dallas, we see Rheem heat pumps last 12 to 15 years on average. The heat and humidity of a Texas summer push systems harder than the manufacturer’s national average. The compressor is usually the last thing to fail; it’s the capacitors, contactors, and defrost components that go first and get replaced several times over the unit’s life. Regular maintenance in spring and fall extends the useful life measurably, especially on the RP14 and RP15 series.
No. The parts that fail on a Rheem heat pump, capacitors, contactors, sensors, boards, are sealed components. There’s no safe field repair for a capacitor or a control board. Replacement is the repair. The good news is these parts are inexpensive compared to a compressor or a full system, and we stock the common ones on the truck so the repair is a single visit. Call (254) 280-5320 for a written quote.
Most component replacements take 45 to 90 minutes on site, including testing the system after the part goes in. A defrost board replacement on an RP16 might run a little longer because of the wiring verification. We confirm the system heats and cools before we leave, and we leave the job site clean. The written guarantee on the repair starts the day the work is done, not the day you call.
We stock the most common Rheem components on our service trucks in Dallas: start and run capacitors, contactors, defrost sensors, crankcase heater thermostats, and certain RP14 and RP16 defrost boards. Less common parts, like specific thermistors or a reversing valve body, we source same day from our local distributors. We also stock parts for Carrier, Trane, and Lennox systems, since Dallas homes run a mix of brands. If we don’t have your exact Rheem part on the truck, we’ll tell you upfront, get the part, and return same day in most cases.
If your Rheem heat pump is limping, call (254) 280-5320 now and tell us what it’s doing. We’ll put a uniformed, background-checked technician at your door, diagnose the problem, and hand you a written price before any work starts. Dalton Heating & Air Dallas is an independent service provider, not affiliated with Rheem, but we’ve been turning wrenches on Rheem equipment across Dallas for years. The estimate is free, the work is guaranteed, and the phone is answered by a real person, 24/7, no voicemail maze.
Written by Marco Benitez, Owner & Lead Technician, Dalton Heating & Air Dallas at Dalton Heating & Air Dallas, serving Dallas and nearby areas.